Two-year results from ENDEAVOR III point to safety, efficacy
April 4, 2007 | Shelley Wood

New Orleans, LA - Two-year follow-up from the ENDEAVOR III trial suggests that the Endeavor zotarolimus-eluting stent may be equivalent to the sirolimus-eluting Cypher stent, in terms of clinical end points. Rates of major adverse cardiac events (MACE) and target lesion revascularizations (TLR) at two years were not statistically different for the two drug-eluting stents (DES), although fewer patients randomized to the Endeavor experienced periprocedural non-Q-wave MI, a difference that was maintained over the two years of follow-up.

Dr Martin Leon (Columbia University, New York) presented the two-year results during the American College of Cardiology 2007 Scientific Sessions last week.

The two-year results are relatively good news for a stent program that appeared poised for a rocky ride when the trial results were first unveiled at the prespecified eight-month follow-up. As reported by heartwire, the Endeavor failed to achieve its primary end point of noninferiority for in-segment late lumen loss at eight months when compared with the Cypher, although clinical and angiographic outcomes were more or less equivalent. At the time, these results were reported by co-primary investigator for the trial, Dr David Kandzari, who has since left academia for Cordis/Johnson & Johnson.

The ENDEAVOR III late results come during a sea change in the DES arena, where the focus has shifted from a fixation on late loss to concerns over stent thrombosis and associated deaths and MI. In the early days of DES trials, minimal or no late loss was held up as the new gold standard. As a result, the eight-month in-stent late loss in ENDEAVOR III for the Endeavor stent, at 0.62 mm as compared with the Cypher at 0.15 mm (p<0.001), and in-segment, at 0.36 mm vs 0.13 mm (p<0.001), led to gloomy speculation about the Endeavor stent's future.

"The original study was meant to have a primary surrogate angiographic end point, and it failed to meet that end point," Leon told heartwire. "But the trial, of course, was planned many, many years ago, before anybody knew that the late loss would be as high as it was with the Endeavor stent, but at the same time before anybody knew that with a late loss of 0.6 mm you could still have TLR in the mid-single-digit numbers. I think we're still learning about the relationship between TLR and in-stent late loss."


Small sample size

The only statistically significant difference between the two groups at 24 months was in MI rates, all periprocedural non-Q-wave MIs, at 0.6% in the Endeavor-treated patients and 3.6% in Cypher-treated patients (p=0.04), a difference that might have been explained by the manner in which events were measured in the trial.

"We don't know exactly why, in this study, the non-Q-wave MI rates were so low," Leon said. "It could be there was less side-branch occlusion, which is something people have hypothesized based on the geometry of the stent design itself. Also, the polymer is very thin—less than 5 µm in total thickness, which means it's almost a quarter of the thickness of the Taxus polymer and less than half the thickness of the Cypher polymer. And it may be that the polymer in and of itself caused less in the way of platelet adhesion, side-branch occlusion, we don't know for sure. You can also argue that this was a relatively small study and sometimes you see statistical significance that may be not biologically meaningful, but just due to the large confidence intervals of a small sample size."

Small sample size could also be scrutinized for other end points. While differences in TLR rates between the two stents were not statistically significant, numerically TLRs were greater in the Endeavor stent-treated patients, while deaths were numerically lower.

ENDEAVOR III: Clinical events at two years

Event
Endeavor, n=313 (%)
Cypher, n=112 (%)
p
All death
1.6
4.5
0.14
Q-wave MI
0
0

Non-Q-wave MI
0.6
3.6
0.04
Stent thrombosis
0
0

TLR
7.0
4.5
0.50
MACE
9.3
11.6
0.47

To download table as a slide, click on slide logo below

Leon told heartwire that the two-year results from ENDEAVOR III alone do not add much to the stent-thrombosis debate, since rates of stent thrombosis per the trial's definition were zero between both stents. However, in an analysis of all the Endeavor stent data out to two years—more than 1300 patients—there have been no reported stent thromboses, he said.

"Now we're beginning to achieve a large-enough sample size where our confidence about late stent thrombosis is increasing," he said. "It's by no means definitive: I'm anxious to see three-year follow-up from ENDEAVOR II and whether these results continue to sustain themselves. But if we don't see significant late stent thrombosis at three years, then I think people will feel more confident that among the DES currently available—the Cypher or Taxus—this appears to have a better safety profile."


The end of surrogate outcomes

At the very least, the two-year ENDEAVOR III results add muscle to the push to exclude surrogate outcomes from primary end points in DES trials.

"I think a lot of people—me included—were a little bit naive," Leon said. "When we heard the RAVEL results, with no late loss and zero restenosis, everyone was ecstatic. But I think we learned since then that probably that degree of late loss reduction does impair healing sufficiently, and it may induce some negative biologic consequences. So I think that people are willing to concede that a somewhat higher late loss is acceptable."

Whether accepting some late loss truly leads to improved safety without sacrificing meaningful reductions in TLR remains to be seen. Three-year results for ENDEAVOR II will be reported at the EuroPCR meeting in May, he noted. Nine-month clinical and eight-month angiographic results from ENDEAVOR IV, with the Taxus stent as the comparator in 1500 patients, are to be presented at TCT 2007.



Your comments
Two-year results from ENDEAVOR III point to safety, efficacy
# 1 of 1
April 11, 2007 05:43 (EDT)
Waqar Ahmed
size, size, size
A study is conceived and powered for a specific end-point. Late-loss (maybe clinically meaningless) is a continous variable and required few hundered patients to compare two stents. While TLR or MACE are categorical variables and require close to thousand patients to compare two stents. (See the number of patients required in REALITY and SORT-OUT II).

It is really wrong to power the study for one variable and then tout that there is no difference in the out-come for another variable for which the study is grossly UNDERPOWERED. Using this example one could compare ACE-Inhibitor versus placebo in 422 patients instead of 4228 patients with LV dysfunction and claim no difference.
--Waqar Ahmed, MD MS FACC

You have to be logged in to add a comment to this article
Login
Username 
Password 
  Forgot your password?
 
Remember me on this computer
 
Join theheart.org community
Five reasons to become a member of the most trusted source of cardiology news:
1Be part of the conversation in our blogs and discussion forum
2Share your thoughts on our news or educational programs
3Receive exclusive newsletters related to your field of interest
4Access unique continuous medical education content
5See and read what leaders have to say about cardiology today
It is free and it only takes five minutes to join!
 
button
Previews
Featured CME
Inside: Interventional/Surgery